Troubleshooting guide, cont’d – BUG-O Systems UNI-BUG III User Manual

Page 43

Advertising
background image

43

Unit runs, but no

Faulty control card

• Unplug the machine from power. Verify there are

speed control.

no bad connections to the control card or on the

board. Replace the card.

Failed speed

• Replace if visually appears damaged. Verify no

potentiometer

loose or broken connections to the part.

Unit runs, but erratic

Poor input voltage

• Verify the machine power source is stable and at

or poor speed control. regulation

the correct voltage. Measure at the outlet.

Faulty control card

• Unplug the machine from power. Verify there are no

bad connections to the control card or board.

Replace the board.

Damaged wheel or

• Turn the machine upside down and off. Replace

wheel assembly

any wheels that are damaged. Replace any idler

wheels that do not freely turn.

Pitted workpiece

• Verify the workpiece is not pitted or damaged in a

way that will give an uneven drive surface to the

machine wheels. Verify the workpiece thickness

does not vary significantly where the machine

wheels travel.

PROBLEM CAUSE

REMEDY

TROUBLESHOOTING GUIDE, CONT’D.

Advertising