Troubleshooting guide – BUG-O Systems Stiffener Welder User Manual

Page 26

Advertising
background image

TROUBLESHOOTING GUIDE

26

PROBLEM CAUSE REMEDY
Does Not Run,

Indicator Light Off.

No Power

To Machine.

Check Power Line Supply

Voltage. Plug In Line

Cord Firmly.

Does Not Run,

Indicator Light Off.

Circuit Breaker

Tripped.

Wiring Shorts. Disconnect Machine And

Examine Internally;

Rewire At Fault.
If None Found, Throw

Direction Switch To “Off”,

Reset Breaker, And Plug In.

Shorted Motor. If Breaker Does Not Trip,

Replace Drive Unit.

Faulty Speed

Control Board.

If Breaker Trips Again,

Replace Control Board.
(OR)

Burned Out

Transformer.

ReplaceTransformer.

Does Not Run,

Indicator Light On.

Bad Connection. Check Wiring Connections,

20 VAC Should Appear

Across Secondary Of

Transformer.

Faulty Speed

Control Board.

If DC Volts = 0 Across

Leads To Motor,

Replace Control Board.

Unit Runs,

But No Control

Over Speed.

Faulty Speed

Control Board.

Replace Control Board.

(Check Connection First).

NOTE:

Make Sure Unit Is Plugged Into Correct Voltage,

(120 VAC, 240 VAC, 42 VAC) Corresponding To Model Number Rating.

20 VAC Should Appear Across Secondary Of Transformer In All Cases.

Advertising