1 - electrical installation - wall box connection, Technical data, Connecting the mains cable – Caple C5210 User Manual

Page 5

Advertising
background image

5

1 - Electrical Installation - Wall box connection

Technical data

230 V AC - 50 Hz

Top conventional oven
– Top element

0.700 kW

– Bottom element

1.100 kW

– Grill element

2.100 kW

Bottom fan oven
– Fan element

2.5 kW

Maximum power rating
– Top oven

2.1 kW

– Bottom oven

2.5 kW

Oven lamp

0.015 kW

300 °C, miniature edison screw

Fan motor

0.025 kW

Maximum power
usable simultaneusly

4,68 kW

Connecting the mains cable

– Remove the two screws securing the

cover plate A behind the cooker.

– Remove the screw C from the cable

clamp.

– Insert the mains cable (type H05RR-

F) of minimum 2,5 mm

2

section into

the cable protector P.

– Connect the phase and earth cables

to the mains terminal connection block
B.

EARTH

N

NEUTRAL

L

LIVE

– Refit the cable clamp so that it clamps

the outer sleeving of the cable.

– Refit the cover plate A.

IMPORTANT:

This appliance must be earthed.

L

N

Green &Yellow
(Earth)

Brown

(Live)

Blue

(Neutral)

P

C

B

A

Fig. 1.1