CONVERSION TO A DIFFERENT TYPE OF GAS

Before converting the appliance for operation with a different gas type, check which type
of gas it is currently set to operate with (adhesive label (Figure 1) on appliance).
For the correct nozzle diameter, refer to the relative table in this booklet.

- Conversion procedure
* Disconnect the electrical power supply to the appliance;
* Change the main oven nozzle:
1) Remove the burner cover plate (see REMOVAL OF THE BURNER COVER PLATE

page 42).

2) Remove the screw securing the oven burner and withdraw the burner from the support

together with the heat sensor and the ignition spark plug. (Figure 5)

3) Remove the nozzle using a 7 mm box wrench (Figure 6)
4) Screw the new nozzle in fully (diameter in hundredths of millimetre stamped on the

nozzle), taking care not to cross the thread.

5) Replace the burner reversing the operations in step 2 above.
6) Replace the cover plate.

Fig. 5

Fig. 6

NOZZLE TABLE

The diameters in hundredths of millimetre are stamped on the nozzle.

Burner

Oven burner

Grill burner

kW

rated load

2,50

2,20

Ø Nozzle bore in

mm

G20

G30

G30

20 mbar

50 mbar

29 mbar

1,13

0,67

0,76

1,12

0,65

0,75