ADJUSTMENT OF THE MINIMUM SETTING FOLLOWING CONVERSION TO A
DIFFERENT GAS TYPE:

1) Conversion from natural gas to LPG:

Ovens with stainless steel front
Turn the temperature control knob to the minimum position, then remove the knob.
Insert a screwdriver through the aperture to engage the bypass screw “A” . Turn the
screw fully to the right (see fig. 4).

Ovens with glass fronts
Remove the front by unscrewing the two ring nuts. Insert a screwdriver through the
hole in the front wall of the oven and turn the screw A fully clockwise.

2) Conversion from LPG to natural gas:

Turn the oven temperature control knob to the “min” position and allow the appliance
to warm up for about 10 minutes.
Then turn the bypass screw anticlockwise to a obtain a low but stable flame. Replace
the front.

After converting the appliance to a different type of gas, remember to change the data
plate to one with the new data (gas type and pressure). (Fig. 1).