CDI-S200 Installation Guide v1.0

12

enable paging). The following examples illustrate this.

Paging may be cancelled – whatever combination of zones has been enabled – with a single

“release” command, which contains no variables.

Note that it is not possible to enable paging via Mic Input 2 by serial control.

EXAMPLE

COMMAND

(ASCII)

COMMAND

(HEX)

Enable paging in Zone 1

<M1,PAXOO/> 3C 4D 31 2C 50 41 58 4F 4F 2F 3E

Enable paging in Zone 2

<M1,PAOXO/> 3C 4D 31 2C 50 41 4F 58 4F 2F 3E

Enable paging in Zones 2 and 3

<M1,PAOXX/> 3C 4D 31 2C 50 41 4F 58 58 2F 3E

Release paging

<M1,PR/>

3C 4D 31 2C 50 52 2F 3E

APPENDIX

Cable lengths

RS-232C serial communication can use either shielded or unshielded cable. The longest cable run

that can be practically used for error-free operation in a given installation will depend on several
factors: cable type, the baud rate used and the amount and type of electrical noise present in the

cable’s vicinity.

A realistic figure for maximum cable length is 250 ft. (76 m.) using good-quality shielded cable and

100 ft. (30 m.) using unshielded cable, at 9600 baud (the most common data rate). However, the

figure may be higher or lower in a particular installation.

Lowering the baud rate will permit significantly longer cable runs to be used.