Mechanical fitting and internal connection – Cloud Electronics CDI-S200 User Manual

Page 6

Advertising
background image

CDI-S200 Installation Guide v1.0

66

Mechanical fitting and internal

connection

If retrofitting the CDI-S200 to an existing
CX263 installation, turn the CX263 off,
remove its IEC mains lead and all other rear

panel connections (marking as necessary to
assist re-connection). If the CX263 is mounted

in a rack, remove it.

If fitting the CDI-S200 to a new CX263,
unpack the CX263.

In either case, place the CX263 on a flat
surface, with the rear of the unit facing you.

1. Undo the six screws securing the top

panel of the CX263; remove the panel.
Retain the screws.

2. Remove the blanking plate covering the

serial interface module connector hole in

the rear panel by removing the two self-

tapping screws securing it.

3. Identify the empty 16-pin header labelled

CON2 on the main PCB behind the
empty serial connector hole. Note there

is an M3 screw immediately behind this
connector, and another about 45 mm to

the right. Both these screws are clearly

marked with arrows; remove and retain

them.





































CX263 PCB: CDI-S200 MOUNTING LOCATION

4. Screw the threaded ends of the two

25 mm mounting pillars supplied with the

CDI-S200 into the holes vacated by the
screws removed in Step 3.

5. On the CDI-S200 board, remove the two

small threaded bushes on the D-type

connector; retain them. An M3 nut-driver
is the best tool for this. Note that these
bushes also retain the metal connector
shell – be careful to keep it in place during
the next two steps.

UNSCREW THESE

TWO BUSHES

RETAIN METAL SHELL

REAR VIEW OF CDI-S200 PCB

6. Plug the connector on the end of the

ribbon cable into connector CON2 on

the CX263 main PCB. Note it can only be
inserted one way round, with the cable

exiting to the left.

7. With the CDI-S200 PCB upside-down,

insert the D-type connector through the

hole in the rear panel. You will see that the
two holes at the other end of the PCB are

aligned with the mounting pillars fitted in

Step 4. Fix the board to the pillars using

the screws removed in Step 3.

8. Replace the two bushes removed in Step

5 adjacent to the D-type connector by

screwing them through the rear panel. The
two self-tapping screws removed in Step 2
are no longer required.

Advertising