7 configuration | mask – Comtech EF Data CDM-760 User Manual

Page 201

Advertising
background image

Ethernet-based Remote Product Management

Revision 2

CDM-760 Advanced High-Speed Trunking Modem

MN-CDM760

7–43

7.4.4.3.7 Configuration | Mask

Use this page to set a mask type for each system-level event.

Figure 7-20. Configuration | Mask Page

Alarm Settings

Use the drop-down list for each item to select Alarm, Fault, Mask, or, where applicable, Fault-Tx

On.

Modem behaviors reflect the set mask state:

Selection (Mask) Event Description

Available Mask State

A

F

M F/T

Ext Reference

Occurs when an external reference is the clock for the modem's TX,

but the external reference does not meet the expected clock rate.

X X X

RxAGC

Occurs when the Receive Automatic Gain Control cannot

compensate for the carrier power level because the carrier has too

little or too much power.

X X X

Es/No Threshold Occurs when the Receive Es/No is at or below the Receive Es/No

Alarm point

X X X

DeComp Invalid

Occurs when packets are received by the demodulator and its

decompression setting does not match the compression setting for

the far side modulator.

X X X

LNB

Occurs when the high or low current limits for the Low Noise Block

Down Converter have been met.

X X X

Eth Link Down

Occurs when an Ethernet Interface is selected using the CONFIG:

Intf menu (Chapter 6 FRONT PANEL OPERATION Sect. 6.2.2.4)

as the active interface, but an Ethernet cable with Ethernet traffic

has not been detected on this physical port.

X X X X

AUPC

Occurs when the Tx output power has reached the Nominal +

Range sum (upper limit) and the modem can no longer increase its

Tx output power, but the remote reported Es/No is still lower than

the Target Es/No.

X

X X