5–10

5.2.2.3.1

Converter X: Mute/Freq

For either side – A or B – the display differs depending on whether the selected module is a BUC

or BDC.

For example, if you select Converter A and it is a BUC:

CONFIG CnvA:

Tx=On

Use the

▼▲ arrow keys to select Tx as either On or Off (muted), and then press ENTER.

Similarly, if you select Converter B and it is a BDC:

CONFIG CnvB:

Rx=On Freq=01980.000MHz

Use the

▼▲ arrow keys to select Rx or Freq. Note that Freq displays only when the module is a

Ku-Band BDC unit.

Use the

▼▲ arrow keys to select Rx as either On or Off (muted), and then press ENTER.

To edit the frequency, use the

◄ ► arrow keys to first select the digit to edit, and then use the

▼▲ arrow keys to edit the value of that digit. Press ENTER when done.

5.2.2.3.2

Converter X: Attenuation

For either side – A or B – and typical whether the selected module is a BUC or a BDC:

CONFIG CnvX: Offst=+2.00

Attenuation = 00.00 dB

Offst (Offset) will display only if the module is an offline unit.

5.2.2.4 CONFIG: RefAdj (Reference Oscillator Adjustment) Menu

Reference Frequency

Adjust: 087

Use this menu for the reference oscillator adjustment. Use the

◄ ► arrow keys to first select the

digit to edit, and then use the

▼▲ arrow keys to edit the value of that digit. Press ENTER when

done.

The default Reference Frequency tuning adjustment is 087, with allowable values from 0 to 255.