4 select: info (information) menu branch, 1 info: remote (remote control) – Comtech EF Data MBT-5000 User Manual

Page 72

Advertising
background image

MBT-5000 L-Band Up/Down Converter System

MN-MBT5000

Front Panel Operation

Revision 4

5–16

5.2.4

SELECT: Info (Information) Menu Branch

INFO:Remote ConvA ConvB

PSA PSB RefOsc

The Info menu branch displays read-only information on the current configuration of the unit.

Use the

◄ ► arrow keys to select from the submenu choices shown, and then press ENTER.

The submenus available from the SELECT: Info (Information) menu branch are as follows:

Submenu

Sect

Function

Remote

5.2.4.1 (Remote Control) Displays when the unit is in Local or Remote mode and gives details

of the interface type selected, etc.

ConvA

ConvB

5.2.4.2 Displays the temperature and RF power for Converter ‘A’ or Converter Unit B.

PSA

PSB

5.2.4.3 Displays the 12V, 7.8V, and 5V power supplies for Power Supply A or 12V and 5V

power supplies for Power Supply B.

RefOsc

5.2.4.4 Displays the raw voltage of the voltage tuning monitor, and the external reference

status.

5.2.4.1 INFO: Remote (Remote Control)

This screen displays when the unit is in Local or Remote mode, and gives details of the interface

type selected, etc. For example:

Remote M&C: 100BaseTx

IP Addr: 192.168.001.004

Press ENTER or CLEAR to return to the previous menu.

5.2.4.2 INFO: ConvA (Converter ‘A’) or ConvB (Converter ‘B’)

Where ‘X’ is the selected converter – Converter (Side) A or Converter (Side) B: This screen

displays the module temperature and, depending on the optional configurations:

For BUCs only, RF Power

For BDCs only, LNA Current

For example:

ConvX: Temp = +34.1 C

RF Power = +10.0 dBm

Press ENTER or CLEAR to return to the previous menu.

ConvX: Temp = +34.1 C

LNA Current = 002.3 mA