5–13

Parameter

Type

Command

(Instruction

Code and

qualifier)

Command

Valid for

PCB or

SSPA

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes – i.e.,

ASCII codes between 48 and 57)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

qualifier)

Query Valid

for PCB or

SSPA

Response to

Query

(Target to

Controller)

Set RTC Time TIM=

ALL 6

bytes,

numerical

Command or Query.
A command in the form hhmmss, indicating the time from
midnight, where hh = hours, between 00 and 23; mm = minutes,
between 00 and 59, and ss = seconds, between 00 and 59
Example: TIM=231259 would be 23 hours, 12 minutes and 59
seconds past midnight.

TIM =
TIM?
TIM *

TIM?

ALL

TIM=xx
(see Description
of Arguments for
details)

Retrieve
Number of
unread
Stored Alarms

N/A N/A 2

bytes,

numerical

Query only.
Returns the number of Stored Events which remain unread, in
the form xx.
Example reply: TNA=18

N/A

TNA?

SSPA

TNA=xx
(see Description
of Arguments for
details)

 

Advertising