5 output sample port connector, j9 – Comtech EF Data TRP500 User Manual

Page 31

Advertising
background image

TRP500-4450 C-band Outdoor Amplifier

Revision 1

System Connections, Installation, and Operation

MN-TRP500

2–3

2.2.4 COMM 1 Connector J6 (Remote Communications/Discrete Cntrl Port)

The COM1/Discrete Control connector J6 is the primary input for
controlling and monitoring the SSPA. It is a 19-pin circular
connector, type MS3112E14-19S. The pinout specification is
contained in Table 2-2.

Mating connector: ITT KPT06J14-19P or MS3116J14-19P.

Table 2-2. Connector J6 Pinout

Pin

Name

Description

A RS485_+RX

B RS485_-RX

C RS485_+TX

D RS485_-TX

E

RS232_RD

Pin 3 of DB9 female connector

F

Ethernet TX+

Pin 3 of RJ45 female connector

G

RS232_TD

Pin 2 of DB9 female connector

H

Ethernet TX-

Pin 6 of RJ45 female connector

J

TX/RX Switch Drive 1 Pos Not for customer use

K

Gnd

Ground (also Pin 5 of DB-9F connector)

L

SUMFLT In

Open when faulted, else tied to Pin K

M

SUMFLT Out

When faulted, tied to Pin K, else open

N

TX Switch Pos 1 Ind

Online/Offline indication

P

RX Switch Pos 1 Ind

Not for customer use

R

+24V

Not for customer use

S

System Mute Control

System muted if customer ties to Pin K

T

Switch Common

GND reference for Pin N

U

Ethernet RX-

Pin 2 of RJ45 female connector

V

Ethernet RX+

Pin 1 of RJ45 female connector

2.2.5 Output Sample Port Connector, J9

The Output Sample port connector is a Type ‘N’ female connector that
provides a nominal -50 dB sample of the output signal. A calibration
label is provided near the connector that shows the actual coupling
values vs. frequency.

Advertising