Comtech EF Data TRP500 User Manual

Page 87

Advertising
background image

TRP500-4450 C-Band Outdoor Amplifier

REVISION 1

Appendix B

MN-TRP500

B–21

Parameter Type

Command
(Instruction
Code and
Qualifier)

Arguments for
Command or
Response to
Query

Description of Arguments
(Note that all arguments are ASCII numeric
codes between 48 and 57)

Response to
Command
(Target to Controller)

Query
(Instruction
Code and
Qualifier)

Response to
Query
(Target to
Controller)

Unit Alarm Mask

MSK=

5 bytes

Command or Query.
Alarm mask conditions. If the mask value for a certain
parameter is set to fault then a fault condition will be
registered if specified hardware conditions are not
met. If the mask value is set to alarm then a fault
condition will only appear to be an alarm that will not
trigger a switchover in a redundant system. If the
mask value is set to masked then the fault will never
be reported to the user.

Example:
MSK=abc’cr’’lf’

Where:
a = Low Forward RF Power
b = Fan Speed
c = High Reverse RF Power

Each parameter can be an integer from 0 to 2.
0 = Fault, 1 = Alarm, 2 = Masked

Default Value: 212

MSK=
MSK?
MSK*

MSK? MSK=abcde


(See description
for details of
arguments)