B.2.2

RS-232

This is a much simpler configuration in which the Controller device is connected directly to the
Target via a two-wire-plus-ground connection. Controller-to-Target data is carried, via RS-232
electrical levels, on one conductor, and Target-to-Controller data is carried in the other direction
on the other conductor.

B.2.3

Basic Protocol

Whether in RS-232 or RS-485 mode, all data is transmitted as asynchronous serial characters,
suitable for transmission and reception by a UART. The character format should be 8N1 (8 data
bits, no parity, 1 stop bit). The baud rate may vary between 2400 and 38400 baud.

All data is transmitted in framed packets. The Controller is assumed to be a PC or ASCII dumb
terminal, which is in charge of the process of monitor and control. The Controller is the only
device that is permitted to initiate, at will, the transmission of data. Targets are only permitted to
transmit when they have been specifically instructed to do so by the Controller.

All bytes within a packet are printable ASCII characters, less than ASCII code 127. In this
context, the Carriage Return and Line Feed characters are considered printable.

All messages from Controller-to-Target require a response – with one exception. This will be either to
return data that has been requested by the Controller, or to acknowledge reception of an instruction to
change the configuration of the Target. The exception to this is when the Controller broadcasts a
message (such as Set time/date) using Address 0, when the Target is set to RS-485 mode.

B.2.4

Packet Structure

Controller-to-Target

Start of

Packet

Target

Address

Address

Delimiter

Instruction

Code

Code

Qualifier

Optional

Arguments

End of

Packet

<

ASCII code 60


(1 character)

0-9

ASCII codes

48-57

(4 characters)

/

ASCII code 47


(1 character)

A-Z, a-z

ASCII codes

65-90, 97-122

(3 characters)

= or ?

ASCII codes

61 or 63

(1 character)


(n characters)

Carriage Return

ASCII code 13


(1 character)

Example: <0412/MUT=1{CR}

Target-to-Controller

Start of

Packet

Target

Address

Address

Delimiter

Instruction

Code

Code

Qualifier

Optional

Arguments

End of

Packet

>

ASCII code 62


(1 character)

0-9

ASCII codes

48-57

(4 characters)

/

ASCII code 47


(1 character)

A-Z, a-z

ASCII codes

65-90, 97-122

(3 characters)

=, ?, !, or *

ASCII codes

61,63,33 or 42

(1 character)

(From 0 to n

characters)

Carriage Return,

Line Feed

ASCII codes

13,10

(2 characters)

Example: >0412/MUT=1{CR}{LF}