10

• The final step is blowing out the dust from the electrical enclosure with the compressed air.

• Turning off power at the circuit breaker and unplugging the communications plug from the top

of the Vortek hoist will make it safe to open up the enclosure.

• Using the same 7/32” hex key, remove the

2 Allen head screws from the top of the

electrical enclosure and swing down

the cover.

• Hint: pushing the cover up at the curved

hinges while swinging the cover down will

help in opening the enclosure.

• Using a low to medium pressure air stream,

gently blow any dirt and dust bunnies from

the ventilation holes from both sides of the

drive inverter.

Note: Safety glasses should be worn during this

procedure.

• Re-install the cover to complete this maintenance portion of the Vortek hoist.

• Last thing to check is the attachment connections for the hoist to the

structural steel.

Check these two 9/16” hex

head bolts for torque

values of 17-20ft/lbs.

Check both sets of clamps.

Check the nuts on the backbone stiffeners for tightness.