Uniformly distribute loads.

Ensure loads are applied to 2 or more lift lines.

• Max. 1500 Pounds Total Applied Load Per Winch

• Maximum live load design capacity on each batten = 30 Pounds Per Linear Foot

• Do Not Concentrate Full-Capacity Point Loads on One Lift Line

Daktronics strongly recommend a thorough understanding of stage rigging practices

before any changes are made to batten loads. Many reference sources are available

that contain important information that will allow you to safely hang heavy loads

once you understand the limitations and dynamics of the materials used in rigging:

wire rope, pipe battens, etc.

2

The Vortek hoist system is a dead-haul system meaning that the load is not counter-

weighted. Each hoist can lift loads only up to the design capacity. Overloading

will result in electrical overload protection shut down of the hoist and possible

damage to rigging components.

Each hoist unit consists of an integral electric motor driven reducer, directly

coupled to a cable drum, which winds steel cables (wire ropes) leading over

sheaves installed within the hoist assembly and along the structural steel of the

building. The cables support battens for attaching the load. The battens can

be lowered to the lower hard struck limit to allow attachment of loads. Refer to

installation drawings for the exact location and dimensions.

Warning:

The VORTEK Batten Hoists are not designed to raise and

lower people. These hoists should NEVER be used for
this purpose.

03

MOTORIZED BATTEN HOISTS

02

BATTEN AND HOIST LOADING INFO