Dataprobe iPIO-8 Operation Manual User Manual

Page 3

Advertising
background image




iPIO-8

Page 3


Power supply

The iPIO is provided with a wall mounted power supply, item
1930075. This power supply is provided with four plug styles to
accommodate most locations. The plug for North America is pre
installed. To remove the plug, slide the tab located under the plug
and lift the plug out. For another location, attach the appropriate
plug to the power supply body. Insert the top of the plug in first,
then slide the tab and insert the bottom of the plug. If a suitable
plug style is not provided, use an adaptor power cord (not
provided) appropriate for your location.

Connect the power supply to the +5VDC connection on the iPIO.
An LED next to the connector indicates power on. The iPIO-8 requires a 1 minute boot-up process.

Power Supply 1930075
Input 100-240 VAC 50-60Hz
Output 5 VDC 2.6A

Network

Connect the network to the iPIO-8 with the Cat 5 cable, provided, or suitable replacement. The
Network connector on the iPIO-8 has two LED indicators. The orange LINK LED indicates a successful
connection to the network. The Green ACT LED blinks to display network activity.

LED Indicators

Pwr

Power On indication


Rmt

Remote Communication Status indication


LED OFF

No Remote Units Programmed

LED ON

All Remotes Communicating Normally

LED Flash

One or More Remotes with Communication Error


Input The iPIO-8 has eight LED indicators, displaying the status of the Inputs.

LED OFF

Input Open

LED ON

Input Closed


During power up sequence, LEDs will be off until boot complete, then flash once, then set to
their current status.

ELK-912-2 to iPIO-8 Connection

Power Supply 1930075 Supplied

Specifications

– ELK-912-2

Operating Voltage : 12 VDC Nominal
Current Draw: 30 mA
Minimum Pull-in Voltage: 9VDC
Diode Protection Across Relay

Contact Rating:

7 Amps @ 30 VDC

10 Amps @ 125 VAC


Physical: 2.2” x 1.55” (56mm x 39mm)