Models 2zrp8, 2zrp9 – Dayton 2ZRP9 User Manual

Page 11

Advertising
background image

11

E

N
G

L

I

S

H

Models 2ZRP8, 2ZRP9

Dayton Operating Instructions and Parts Manual

Symptom

Possible Cause(s)

Corrective Action

Troubleshooting Chart

Engine will not start

Generator has no output.

Engine switch is off.

Fuel Tank empty.

Fuel Valve is off.

Inadequate engine oil.

No spark at spark plug.

Circuit breakers tripped.

Inadequate cord sets or extension cords.

Turn engine switch to the ON position.

Fill tank per instructions in this manual.

Turn Fuel Valve on.

Check oil level. This engine is equipped
with a low oil sensor. The engine cannot
be started unless the oil level is above
the prescribed lower limit.

Remove the spark plug cap. Clean any
dirt from around the plug base, then
remove the spark plug. Install the spark
plug in the plug cap. Turn the engine
switch on.
Grounding the electrode to any engine
ground, pull the recoil starter to see if
sparks jump across the gap. If there is no
spark, replace the plug.
Reinstall the plug and start engine
according to instructions in this manual.

Consult Customer Service.

Reset circuit breakers.

Check cord sets or extension cords
capabilities in section Controls; Cable
Size in this manual.

Consult Dayton Customer Service.

Advertising
This manual is related to the following products: