Short Form Calibration

D3831 Rev B

GT400 User’s Manual

15

CALIBRATION NUMBER

The “CAL” number is adjusted to make scale read proper weight for different

load cells and to make accuracy adjustments on a scale system. Systems

should be checked with known weights and adjusted if necessary to insure

accuracy. Both setup and calibration numbers are changed to convert a scale

from lbs to kgs.

Calibrating Scale For Maximum Accuracy

Note:

To accurately calibrate scale, you need a large amount of weight that

has a known value. For best results you should have at least as much weight

as largest load you plan to weigh.

Determining New Setup and

Calibration Numbers

The setup number does not change.

1. Press to Zero-Balance.
2. Put KNOWN WEIGHT on scale

platform and write down DISPLAY

WEIGHT.

Perform following equation to find

ACCURATE CAL NUMBER.