Operators Manual

D3674

1

The Cab Control 400 allows the loader operator to

communicate via radio signal to a properly equipped EZ

indicator. Once in contact with an indicator, the Cab Control

allows the loader operator to view the indicator display and

control the indicator by pressing buttons on the Cab Control

front panel.

Mounting Location
Metal structures surrounding the indicator and the Cab

Control 400 may block the radio signal. The Cab Control

400 is designed to work with the EZ indicator mounted

inside the cab of a truck and the Cab Control 400 mounted

in a loader or tractor cab at dashboard level or above.

Connecting Power
Power can be obtained directly from either a 12 Volt or a 24

Volt electrical system or for stationary applications, from a

120VAC to 12VDC power cube that plugs into a wall outlet.

Warning!

Disconnect the Cab Control 400 power cord

before jump-starting or fast-charging the

battery.

Connect the RED wire from the power cable to 12VDC or

24VDC and the BLACK wire to GROUND. The Cab Control

400 is fused internally at 2 Amps but typically uses less than

0.20 Amps. Orange and Blue wires are not connected.

Wire Color

Wire Function

RED

Battery (+12VDC)

BLACK

GROUND