0 – mains power requirements – EM Acoustics X3-DFSP self-powered downfill element User Manual

Page 9

Advertising
background image

Page 9 of 36

X3-SP User Manual

v1.0 May 2012

3.0 – Mains Power Requirements

3.1 - Power Supply

Both the X3-SP and X3-DFSP utilize UMAC

TM

Class-D amplifier modules with Power Factor

Correction (PFC) power supplies, ensuring universal mains voltage operation. The
amplifier modules can safely operate with voltage ranges from 100-120VAC and 200-
240VAC. Important Note – please be aware that using these products on 100-120VAC
will draw more current from the mains supply than using at 200-240VAC.

3.2 - AC Input Connector (BLUE)

The blue Neutrik PowerCON connector supplies mains power to the X3-SP and X3-DFSP.
This connector is rated at 20 amps and is locking to prevent accidental disconnection. Any
additional loudspeakers connected to the MAINS LINK (GREY) connector also take their
power from this primary input connector, and as such you must ensure the total load does
not exceed 20 amps.

3.3 - AC Link Connector (GREY)

The grey Neutrik PowerCON connector supplies mains power to additional loudspeakers in
the chain. The PowerCON connector is a locking design, which prevents accidental
disconnection. Cables used to connect additional loudspeakers should be of a suitable
gauge to support the potential current draw from multiple loudspeakers.

3.4 - Maximum Number of Looped Mains Connections

It is very important that the total current draw does not exceed 20 amps. Please
remember that any loudspeaker connected in the chain will draw its power from the blue
mains input connector on the first loudspeaker in the chain. Detailed below are the
maximum recommended numbers of X3-SP and X3-DFSP loudspeakers that can be
connected at different voltage and supply current limits.

20-amp supply limit:

Product

115VAC

230VAC

X3-SP

3 looped (4 total)

6 looped (7 total)

X3-DFSP

3 looped (4 total)

6 looped (7 total)

16-amp supply limit:

Product

115VAC

230VAC

X3-SP

2 looped (3 total)

5 looped (6 total)

X3-DFSP

2 looped (3 total)

5 looped (6 total)