Troubleshooting, Safety guidelines, Accessories – ENVIROMAC 103 Snorkvac User Manual

Page 14: Light kit, Hoods, Mounting brackets, Fans, Pivoting booms, The arm will not stay where it is placed, Stronger resistance during rotation of the arm

Advertising
background image

Troubleshooting.

Symptoms

Possible reasons

Solution

The arm will not stay
where it is placed

The joints require adjustment

Adjust the joints (item VIII)

Stronger resistance
during rotation of the
arm

Lack of grease in the rotating socket Grease the rotating socket

Decrease in air volume

A/ Hose not properly connected to
Arm tubes.
B/ The flexible hose is damaged.
C/ The Damper is closed

A/Reconnect Hose.

B/ Replace Damaged Hoses.
C/ Open Arm Damper

Safety guidelines.

For the safe operation of the ENVIROFLEX® SNORKVAC™ self-supporting Fume Arms:

• DO NOT rotate the arm beyond the noticeable "resistance" (4”, 6” and 8” versions).

• DO NOT bend it beyond vertical axis of the rotating socket.

ACCESSORIES

Light kit

The light kit includes an LED lamp with hood switch, wires and mounting brackets for the hood.

Hoods

• You can get optional extension hoods.
• φ14” for 6” arm

• φ20” for 8” arm

Mounting brackets

Wall brackets see Drawing 2.

Ceiling Brackets

Fans

A variety of fans are available with various voltages, HP and CFM requirements

Pivoting booms

Numerous lengths and styles of boom are also available.

Advertising