CPXS, CPXNS and CPXPS USER INSTRUCTIONS ENGLISH 71569250 07-11
Page 10 of 48
flowserve.com
Typical sound pressure level L
pA
at 1 m reference 20
µ
Pa, dBA
3 550 r/min
2 900 r/min
1 750 r/min
1 450 r/min
Motor size
and speed
kW (hp)
Pump
only
Pump and
motor
Pump
only
Pump and
motor
Pump
only
Pump and
motor
Pump
only
Pump and
motor
<0.55(<0.75)
72
72
64
65
62
64
62
64
0.75 (1)
72
72
64
66
62
64
62
64
1.1 (1.5)
74
74
66
67
64
64
62
63
1.5 (2)
74
74
66
71
64
64
62
63
2.2 (3)
75
76
68
72
65
66
63
64
3 (4)
75
76
70
73
65
66
63
64
4 (5)
75
76
71
73
65
66
63
64
5.5 (7.5)
76
77
72
75
66
67
64
65
7.5 (10)
76
77
72
75
66
67
64
65
11(15)
80
81
76
78
70
71
68
69
15 (20)
80
81
76
78
70
71
68
69
18.5 (25)
81
81
77
78
71
71
69
71
22 (30)
81
81
77
79
71
71
69
71
30 (40)
83
83
79
81
73
73
71
73
37 (50)
83
83
79
81
73
73
71
73
45 (60)
86
86
82
84
76
76
74
76
55 (75)
86
86
82
84
76
76
74
76
75 (100)
87
87
83
85
77
77
75
77
Note: for 1 180 and 960 r/min reduce 1 450 r/min values by 2 dBA. For 880 and 720 r/min reduce 1 450 r/min values by 3 dBA.
2
TRANSPORT AND STORAGE
2.1 Consignment receipt and
unpacking
Immediately after receipt of the equipment it must be
checked against the delivery/shipping documents for
its completeness and that there has been no damage
in transportation. Any shortage and/or damage must
be reported immediately to Flowserve Pump Division
and must be received in writing within one month of
receipt of the equipment. Later claims cannot be
accepted.
Check any crate, boxes or wrappings for any
accessories or spare parts that may be packed
separately with the equipment or attached to side
walls of the box or equipment.
Each product has a unique serial number. Check
that this number corresponds with that advised and
always quote this number in correspondence as
well as when ordering spare parts or further
accessories.
2.2 Handling
Boxes, crates, pallets or cartons may be unloaded
using fork lift vehicles or slings dependent on their
size and construction.
2.3 Lifting
A crane must be used for all pump sets in
excess of 25 kg (55 lb). Fully trained personnel
must carry out lifting, in accordance with local
regulations.
Slings, ropes and other lifting gear should be
positioned where they cannot slip and where a
balanced lift is obtained. The angle between two
load carrying slings or ropes must not exceed 60°
2.3.1
Bare pump
The bare pump should be lifted as shown: