Byron Jackson Double Mechanical Seal Submersible Pumping Unit • 1042.293/9 • June

04

Page 42 of 68

5. Rotate the tool over the buckle, backing of

with tension handle throughout the entire
course of the bend.

Failure to back off with tension handle
throughout the entire course of bend may re-
sult in breaking of band. There is no loss of
tension, as the band released is used up in
the bend.

Figure 33 Use of "Band-It" steel band, step 5

6.

Pull the cutter handle to cut the band.

Figure 34 Use of "Band-It" steel band, step 6

7.

Remove the tool holding the stub of the band
down with your thumb.

Figure 35 Use of "Band-It" steel band, step 7

8.

Lock the stub by hammering down the buckle
ears, thus completing the BAND-IT clamp.

Figure 36 Use of "Band-It" steel band, step 8