Page 58 of 68 – Flowserve Byron Jackson Type M User Manual

Page 58

Advertising
background image

®

Byron Jackson Double Mechanical Seal Submersible Pumping Unit • 1042.293/9 • June

04

Page 58 of 68

FAULT SYMPTOM

Motor protection triggered

⇓ Pump does not start

⇓ Flow inadequate

⇓ Pumping unit runs, but does not pump

⇓ Shut-off head current (amps) is higher than originally recorded but shut-off head is not diminished

⇓ Shut-off head is diminished but shut-off current (amps) is unchanged

⇓ Shut-off head is diminished and shut-off current (amps) is much higher

⇓ Duty capacity and head are low but running current (amps) and shut-off valves are normal

⇓ Pump starts bus trips circuit breaker

⇓ Pump does not start

PROBABLE CAUSES

POSSIBLE REMEDIES

z

Blockage in discharge or intake

Disassemble and clean discharge and
intake.

z

Valve in system is not fully open

Fully open valve

C. ELECTRICAL TROUBLES

z Motor

circuit

breaker

adjusted

too

low.

Readjust motor circuit breaker
according to rating plate or Chapter
12.2 "Data sheet".

z Current

consumption

of

motor

too

high

due

to

under voltage or wrong frequency.

Check system voltage and frequency.
Check if the information on the type
plate corresponds with the system
voltage and frequency.

z

Phase failure.

Check fuses.

Examine power cables for damage.

z Voltage

failure

due

to

blown

fuse(s).

Replace

fuse(s).

z Defective

power

cable.

Replace

power

cable.

z Incorrect

rotating

direction.

Change

rotating

direction.

z Rotating

speed

too

low

because

of

under

volt-

age or wrong frequency.

Check system voltage and frequency.

z Rotating

speed

too

low

because

motor

runs

with one phase.

Check fuses.

z Rotating

speed

too

low

due

to

bearing

dam-

age.

Remove pumping unit and repair.

z z Drop

in

line

voltage

If

amperage

remains

within

110

%

of

the rated value: No remedy necessary.

If amerage does not remain within
110 % of the rate value: Check line
voltage

z

Insulation failure

Measure insulation resistance.

z Insulation failure

Measure insulation resistance.

Check voltage.

z Pumping unit is stuck

Try momentarily reversing rotation by
interchanging any two leads