General Installation and Maintenance Instructions for Machinery Components

9

6.2 Installation of a Cartridge Type Seal

with Centring Tabs

See figure 7

6.2.1 Check assembly drawing, bill of material and seal assembly prior to installation.

6.2.2 Install the seal onto the shaft and locate the gland against the face of the seal chamber.

6.2.3 Orient the connections on the seal gland(s) as indicated by the seal assembly drawing

and connecting piping.

6.2.4 Install gland bolts/nuts, but do not tighten. The gland must be free to move radially.

6.2.5 Complete the remaining equipment assembly including thrust bearings, if applicable.

6.2.6 Ensure the centring tabs are correctly located and engaged.

Incorrect position of the setting plates can lead to malfunction of the mechanical seal
and consequent leakage of sealed product into the environment.

6.2.7 Evenly torque gland bolts/nuts to prevent cocking of the gland or uneven gland pressure

against the seal chamber.

6.2.8 Tighten drive arrangement screws to the torque values shown on the seal assembly

drawing .

Inaccurate tightening of these screws can lead to unsafe situation as mechanical seal
may move out of the seal chamber when pressure is applied.

6.2.9 Assemble interconnecting piping as per API-plan and piping instructions as given in

paragraph 7. See also (if applicable) auxiliary system installation and maintenance manual.

6.2.10 Remove centring tabs and store them in a known place.

6.2.11 Inspect equipment and driver alignment in accordance with coupling and / or equipment

manufacturer's instructions.

6.2.12 After bringing the unit up to operating conditions (pressure and temperature), recheck

pump to driver alignment. Make adjustments as necessary.

!