Step 7 Observe the length of the
lock pin
outside of the gland.
The pin should extend
2.5 to 4.8 mm (0.10 to 0.19
inch) from the gland. If it is
more or less than this,
remove the gland and
recheck the installation.
Step 8 Pry off the centering devices
with a screwdriver.
Step 9 Connect the flush line to the gland if required.
Step 10 Turn the shaft by hand as a final check to be sure nothing is binding.
2.5 to 4.8 mm
5
Step 8
Step 7