Audio Service Parameters

Figure 5-4 Audio Service Parameters

Input Meters show the input level of the channels enabled in the current encoding
mode in dBFS.

Audio Bandwidth displays the current audio bandwidth of the main channels. This is
dependent on the number of channels being encoded and the data rate.

Pass Through indicates if the unit is in pass-through mode, (i.e., a pre-encoded
bitstream has been detected).

Figure 5-5 Encoder Stop and Start Buttons

Encoder State displays the status of encoding for the current device.

Not Encoding: The user has requested that the unit start encoding, but the

encoder is unable to encode because it is missing a required input signal, or
the timecode start value has not been reached.

Encoding: The unit is encoding.