Technical Data

Type Approval N°
NRGS 16 -1: TÜV · WRB · 96-388
NRGS 16 -1 S: GL 99250-96 HH

Max. service pressure
32 bar g at 238 °C

Connections
Screwed 1" BSP, DIN ISO 228
Flanged DN 50, PN 40, DIN 2635

Materials
Case:

Die cast aluminium 3.2161 (G AlSi8Cu3)

Stem:

S. S. 1.4571 (CrNiMoTi 17 12 2)

Flange:

Forged steel 1.0460 (C 22.8)

Measuring electrodes: S. S. 1.4571 (CrNiMoTi 17 12 2)
Electrode insulation:

PTFE

Spacer disc:

PTFE

Lengths supplied

1

500 mm

1000 mm
1500 mm

Mains supply
230 V +/- 10 %, 50/60 Hz
115 V +/- 10 %, 50/60 Hz

1

24 V +/- 10 %, 50/60 Hz (option)

Power consumption
5 VA

Fuse
Thermal fuse T

max

= 102 °C

Sensitivity
Range 1: 10

µ S/cm

Range 2: 0.5

µ S/cm

Electrode voltage
10 V

ss

Output
4 volt-free relay contacts.
Max. contact rating with a switchting voltage of 24 V, 115 V and 230 V a. c.: ohmic 4 A,
inductive 0.75 A at cos

ϕ

0.5. Max. contact rating with a switching voltage of 24 V d. c.: 4 A

Contact material: silver, hard-gold plated

Energizing/deenergizing delay
3 sec., factory set