Low battery indication—level 2, Calendar clock stopped – Denso BHT-100Q User Manual

Page 146

Advertising
background image

130

(When the dry battery cartridge
is loaded)

(When the rechargeable battery
cartridge is loaded)

Low battery indication—Level 2

Problem

When the power is turned on or off or during ex-
ecution of program (System Mode or application),
the battery output level has lowered.

If lower battery is detected, the BHT beeps
five times (for 0.1 second per beep) and then
turns itself off. Depending upon the battery
level, the beeper may not sound five times.

Solution

If the BHT is loaded with the rechargeable battery
cartridge, replace or charge it. (For the charging
procedure, refer to Chapter 5, Section 5.5.)

If the BHT is loaded with the dry battery cartridge,
replace the dry cells.

Calendar clock stopped

Problem

The calendar clock integrated in the BHT has
stopped because:

- The battery cartridge had been removed for a

long time,

- The rechargeable battery cartridge had not been

recharged for a long time, or

- The dry cells in the dry battery cartridge had not

been replaced.

The indication of 00/01/01 00:00 will vary
depending upon the calendar clock state.

Solution

Set the calender clock (refer to Chapter 2, Subsec-
tion 2.3.2).

Advertising