Denso BHT-100Q User Manual

Page 76

Advertising
background image

60

• MaxiCode

Example: If a code read is "MaxiCode and Mode 4," then the option data below will
follow.

(Data read)… X4

Minimum number of digits to be read for ITF or Codabar

You may set the minimum number of digits to be read for ITF and Codabar. Setting a
small number of digits increases the frequency of digit-missing reading or misreading
depending upon how to scan bar codes or the quality of bar codes. On the other hand,
setting a large number will diminish the possibility of those errors.

The setting range is from 2 to 20 for ITF and from 3 to 20 for Codabar. The default is 4
for ITF and Codabar.

• PDF417

Example: If a code read is "PDF417, Error correction level 4, 12 rows and 2 digits," then
the option data below will follow.

(Data read)… Y1041202

Data read

Option data

"Y"

1

2

3

n-1

n

n+1

n+2

n+3

n+4

n+5

n+6

n+7

n+8

Reserved
1

Error
correction
level

No. of rows

No. of digits

"X"

1

2

3

n-1

n

n+1

n+2

Mode

Data read

"Z"

1

2

3

n-1

n

n+1

n+2

n+3

n+4

n+5

n+6

n+7

n+8

Reserved
0

Error correction level

n+9

n+10

n+11

No. of cells (height)

No. of cells (width)

Data read

Option data

• Data Matrix

Example: If a code read is "Data Matrix, Error correction level ECC200, 10 cells wide by
10 cells high," then the option data below will follow.

(Data read)... Z0200010010

Advertising
This manual is related to the following products: