143

Chapter 5. Handling the CU-7000 (Option)

5.4.3 Interfacing with the Host Computer

This section describes how to start communication with the host computer in System
Mode. The same may apply when you use a user program.

(1)

Turn the host computer on.

(2)

Plug the AC adapter of the CU-7000 into the wall socket.

(3)

Make sure that the BHT is turned off, then set it on the CU-7000.

(4)

Turn the BHT power on and run System Mode. Set the communications environ-
ments (communications protocol, interface port, communications parameters,
and protocol options).

Regarding the communications protocol: When using Ir-Transfer Utility C/Ir-
Transfer Utility E on the host computer, select the BHT-Ir protocol; when using
Transfer Utility, select the BHT-protocol.

Regarding the interface port: Select the optical interface port.

(5)

On the host computer, initiate a communications program (e.g., Ir-Transfer Utility
C/Ir-Transfer Utility E/Transfer Utility, or equivalent).

(6)

To transfer data stored in the BHT to the host computer, select "3: UPLOAD" on
the SYSTEM MENU in System Mode. To transfer data from the host computer to
the BHT, select "2: DOWNLOAD." (For details, refer to Chapter 2, Section 2.5.)

The BHT and the host computer will start communications with each other via the
CU-7000. The DATA LED will come on upon start of communications. After
completion of communications, the LED will go off.

(7)

Unplug the AC adapter of the CU-7000 from the wall socket.

Advertising
This manual is related to the following products: