Installation instructions, Testing lp gas safety shut off, Electrical connection – Dometic RM2852 User Manual

Page 8

Advertising
background image

- 8 -

INSTALLATION INSTRUCTIONS

Testing LP gas safety shut off

The gas safety shut off must be tested after the refrigerator is

connected to LP gas supply.

RM2354-2454-2554-2662-2663-2862-3862 &NDR1062

To test the gas safety shut off, follow these steps:

Start the refrigerator. Switch to GAS mode.
Check that the gas fl ame is lit and the GAS mode

indicator lamp is on.
Close the manual gas shutoff valve at the back of the

refrigerator.
Wait for approx. 6 minutes. The CHECK indicator

lamp should be lit and the GAS mode indicator lamp

should be off.
Remove the protection cover.
Open the manual gas shutoff valve. Do not change

any button positions on the control panel.
Apply a non corrosive commercial bubble solution

to the burner jet orifi ce. No bubbles should appear at

the opening of the burner jet orifi ce. The presence of

bubbles indicates a defective gas safety shutoff, and

service is required.
If no bubbles are present at the burner jet orifi ce,

rinse it with fresh water. Be careful not to damage

the burner jet orifi ce.
Put back the cover.
Press the ON/OFF button once to turn the refrigera-

tor off and then press it again to turn the it back on.

Normal operation of the burner should return.
Allow the burner to operate for a minimum of fi ve

minutes.

RM2351-2451-2551-2652-2852

To test the gas safety shut off, follow these steps:

Start the refrigerator without connecting to

120 V AC.
Check that the gas fl ame is lit. In AUTO mode the

AUTO mode indicator lamp is on.
Then, follow steps 3-11 in instruction above.

1.
2.

3.

4.

5.
6.

7.

8.

9.

10.

11.

1.

2.

3.

Electrical connection

120 V AC connection

The refrigerator is equipped with a grounded three-prong plug

for protection against shock hazards. It should be plugged di-

rectly into a properly grounded three-prong receptacle. Do not

cut or remove the grounding prong from this plug!
The free length of the cord is 2 feet. It should be routed to

avoid direct contact with the burner cover, fl ue cover or any

other components that could damage the cord insulation.
To allow easy access through the vent door, it is recommended

that the receptacle is placed:

To the left of the refrigerator. (On the opposite side of the

refrigerator burner assembly.)
3” above the refrigerator mounting fl oor

(

RM2662-2663- 2862-3862 & NDR1062

).

4-6” above the refrigerator mounting fl oor

(

RM2351-2354

)

6” above the refrigerator mounting fl oor

(

RM2451-2454- 2551-2554-2652-2852

).

120 Volt AC

receptacle

3” / 6” from the bottom

of the plastic receptacle

above the fl oor

120 V AC

120 V AC

receptacle

Advertising