Surface-Mount using 236-00x Series or Model 238-001 Enclosure

N

OTE

: The back box is not required for use with a Model 236 Series or Model 238-001 Surface-Mount

Enclosure and should be removed.

1. Drill or punch conduit entries. (The Model 238-001 already includes a rear-access hole with gasket.)

WARNING

To prevent accidentally damaging equipment, drill all holes before

mounting the telephone.

2. Install the telephone line suppressor (customer-supplied) on the telephone line, if applicable.

3. Connect the telephone’s modular plug to the incoming subscriber line or the telephone line suppressor

(if applicable) using the appropriate mating connector.

4. Complete the installation by attaching the telephone’s front panel to the mounting flanges of the Model

236 Series or 238-001 Surface-Mount Enclosure using the six supplied #10-32 security screws and the
six black flat washers. A Model 233-001 Security Screwdriver (sold separately) is required for
installing the security screws. 10–12 in-lbs. of torque is recommended.