Model 226-001, 246-001, 256-001, and 276-001 Industrial Telephones with Keypads

Page 2 of 18

f:\standard ioms - current release\42004 instr. manuals\42004-337f.doc
06/12

Installation

ATTENTION

Installation should be performed by qualified personnel and only in

accordance with the National Electrical Code or applicable local codes.

Safety Guidelines

When installing any GAI-Tronics telephone equipment, please adhere to the following guidelines to
ensure the safety of all personnel:
 NEVER install telephone wiring during a lightning storm.

Install a UL Listed lightning arrestor on any telephone installed where the telephone or telephone

cable is at risk of being exposed to lightning strikes. The lightning arrestor must be installed as close
as possible to maximize the protection. It must not be installed within the enclosure supplied with the
telephone. Please consult our Service Center at 800-492-1212 for further information.

 Do not install telephone jacks in wet locations unless the jack is specifically designed for wet

locations.

 Do not touch uninsulated telephone wires or terminals unless the telephone line has been

disconnected at the network interface.

Security Hardware

Models 226-001 and 276-001 are vandal resistant, with the front panel for each telephone attached to its
enclosure with security screws. A GAI-Tronics Model 233-001 Security Screwdriver or Torx T-25
security head tip (sold separately) is recommended for installing the security screws. Model 246-001 and
256-001 Telephones’ front panels are attached with standard Phillips head screws.

Conduit Installation Details (Applicable to Models 246-001 and 256-001)

GAI-Tronics recommends installing telephone lines in conduit to protect against accidental damage and
vandalism. To prevent moisture from entering the enclosure, we strongly recommend the following:
 Conduit should enter the enclosure from the bottom whenever possible.
 Sealed fittings should be installed at all cable entry points.
 Silicone sealant or equivalent should be applied around and inside all conduit entries to prevent

moisture ingress.