Guntermann & Drunck GmbH

Installation and operating manual
TripleMUX/QuadMUX

ENTER

Cancels the input and goes to the Console Setup menu. The new user

password is saved.

ESC

cancels the input without changes.

The changes made here have no effect whatsoever on your master
password.

5.2.2.17 Changing the master password

Note:
To run this function you need to be logged on as a master!

If you want to change the default value according to Appendix

A in the manual,

move the c

ursor in the Console Setup menu onto the "Master Password“ field

and then press the

ENTER

key.

Another menu will appear which prompts you to enter the new password.

C H A N G E P A S S W O R D T r i p l e M U X

Please enter your new

password twice:

[Min. 4, max. 12 characters]

Esc

Enter


Otherwise prompt in the same way as in

chap. 5.2.2.16

.

5.2.2.18 Setting the OpenAccess

Note:
To run this function you need to be logged on as a master!

With access via OpenAccess anyone can access the TripleMUX and the
connected PCs.

The OpenAccess is defined as follows with the factory settings:

ƒ

Access to the connected PCs without logging on first with login name
and password

ƒ

Authorisation to perform the AutoScan

ƒ

Access to the Console Setup menu (restricted)

ƒ

Authorisation for manual logout using

F8

ƒ

Authorisation to re-initialise the mouse

Page 25