10 fuse, Fuse – IDK VAC-5000HD User Manual

Page 48

Advertising
background image

VAC-5000HD User’s Guide

48

10 Fuse

The VAC is equipped with a glass tube-type fuse (5 × 20 mm/0.2 x 0.79”), which prevents overcurrent from

flowing into the VAC when a circuit or circuit part is broken.

If the VAC cannot be turned on, first check if the fuse placed in the AC inlet is blown or not. If it is blown,

replace the blown fuse with the spare fuse by following the procedure below.

1.

Turn off the VAC and unplug the power supply plug.

2.

Remove the power connector from the AC inlet

3.

Remove the fuse holder by pulling out the depressed portion of the connection area for power

supply connector using a screw driver or the like.

[Figure 10.1] Fuse holder

4.

Replace the current fuse with the spare fuse.

Spare Fuse

Blown Fuse

[Figure 10.2] Replacing fuses

5.

Put the fuse holder back into the original position

Note: In case the fuse blows again even after the blown fuse is replaced, the product may have problems.

Please contact your dealer.

Advertising