4 sfp (small form-factor pluggable) module, Sfp (small form-factor pluggable) module – IDK OPF-H1000-A User Manual

Page 15

Advertising
background image

OPF-TH1000-A/OPF-RH1000-A User’s Guide

15

5.3 Fiber optical cables for long distance transmission

Use correct fiber optical cables to maximize the performance of the OPF-H1000.


● Use a duplex fiber or two simplex fiber cables with LC connectors at both ends.
● To polish connectors:

For SFP module for multimode: PC polishing is recommended.

For SFP module for singlemode: UPC polishing is recommended.

Note: APC polishing is not supported.

● Make sure that the fiber optical cable to be connected between the transmitter and receiver meets the

standard of the desired extension distance.

● Extension distance varies depending on attenuation of the fiber, connector and other contact portions.
● Before inserting or removing the fiber, make sure to first turn the OPF-H1000 off and not to touch the ends

of the fiber. Clean up the fiber before inserting it again.

♦ Simplex fiber and duplex fiber

Simplex fiber has an optical fiber and a connector at both ends while duplex fiber has two fibers and

two connectors. The duplex fiber cable is recommended for OPF-H1000, but signals can be transmitted

using two simplex fiber cables.


♦ LC connector

One of connectors for fiber optical cables. (Example: SC connector, FC connector, ST connector, MU

connector)

5.4 SFP (Small Form-factor Pluggable) module

The fiber type and extension distance to be used vary depending on the SFP module.

[Table 0.1] Specifications of standard SFP modules

*Some SFP modules for singlemode can extend the transmission distance up to 30 km with OS1. Please

contact us if needed.


Notes:

● Use only the supplied SFP module to ensure the best system performance and reliability.

● Plug the dust cap to the fiber optical cable if not connecting the cable.

● Pull the lever of the SFP module to remove it. Lock the lever and push it into until it clicks to attach the

module.

Multimode fiber

Singlemode fiber

Connector

LC (Duplex)

Wave length

850 nm (Oxide VCSEL laser

*

)

1310 nm (Fabry-Perot laser

*

)

Maximum extension

distance

OM3: 300 m/984.25 feet

OM4: 1 km/3280.84 feet

OS1 : 4.7 km/15419.94 feet

Output level

-9 dBm to -2.5 dBm

-8.4 dBm to -3 dBm

Input level

-13 dBm or higher

-18 dBm or higher

Advertising