4 functions and features, 5 installation of the encoder, 1 settings of the encoder – ifm electronic RM9000 User Manual

Page 6: 2 signal assignment

Advertising
background image

CANopen encoder

6

4 Functions and features

● There are 1 SDO server and 2 default value PDOs according to CiA DS 301�

The PDO mapping can be changed (dynamic PDO mapping)� The default value

identifiers have been assigned according to the "predefined connection set" in

the CANopen specification�

● The COB IDs of the PDOs and their baud rate can be configured�

● The module expects a sync object� The CAN identifier of the sync object can

be configured�

● The module supports "node guarding" and "heartbeat"�

● The module supports an emergency object� The COB ID of the EMCY object

can be configured�

● The module stores the last error� The error code of the corresponding

emergency object is stored�

● The module supports the load command (reset function to restore the factory

settings)�

● Alarms and warnings are not displayed�

5 Installation of the encoder

Attention: This product corresponds to the standard EN 61000-6-4� The unit may

cause radio interference in domestic areas� Where applicable, the user has to take

appropriate measures to avoid these�
5.1 Settings of the encoder

► Set the node address of the encoder, the baud rate and the bus termination

before set-up of the device via software�

5.2 Signal assignment

Signal

5-pole M12 connector

1

2

3

4

5

CAN GND

pin 1

24 V supply voltage

pin 2

GND (PE)

pin 3

CAN high

pin 4

CAN low

pin 5

► Use screened cable�

Advertising