Low flame adjustment of burners – ilve Freestanding Cookers User Manual

Page 45

Advertising
background image

When installing the appliance it is recommended to check that the burner minimum speed (Low Flame

Setting) has been correctly adjusted. If it is necessary to change the type of gas, adjustment of the low

flame setting must be completed by the installer. To adjust the minimum setting for the burners the

following steps must be completed

Minimum flow of valve cooking hob taps

• Switch on the burner and turn the control knob towards the minimum flow position;

• Remove the knob;

• Using a screwdriver, adjust the internal screw until the correct low flame is obtained, the screw is

located just to the right of the shaft see figure 1

• Refit the knob.

Minimum flow of non-valved cooking hob taps

• Switch on the burner and turn the control knob towards the minimum flow position;

• Remove the knob;

• Insert a small screwdriver into the shaft of the gas valve and adjust the internal screw until the correct

low flame is obtained; see figure 2

• Refit the knob.

• Unscrew the adjustment screw to increase the flow, or tighten it to reduce the flow.

• The adjustment is correct when the low flame measures approximately 3 or 4 mm.

• For ULPG the adjustment screw should be turned fully clockwise.

• Make sure the flame does not go out when changing quickly from maximum flow and vice versa.

ENSURE THE MINIMUM FLAME WILL NOT BE EXTINGUISHED BY AIR DRAUGHTS

low flame adjustment of burners

freest

anding cookers

45

ILVE Freestanding Operating Manual

Advertising