Ancillary service information – ilve Freestanding Cookers User Manual

Page 47

Advertising
background image

Pressure Adjustment

First turn the gas off to the appliance. Remove the sealing screw from the regulator’s test point at the

rear of the appliance and place the hose of the Manometer onto it. Turn the gas on to the appliance and

light the Wok Burner and Small Burner at maximum setting. Check the pressure and adjust at the regulator

if necessary to the setting in the table on the last page or the Data plate. For ULPG Gas adjust at the

regulator on the cylinder – Turn regulator adjusting screw clockwise increases pressure whilst

anti-clockwise decreases pressure. Refit the test point sealing screw when finished.

Electrical Equipment and Components

Electrical componentry is primarily located below the hob surface. Removal of the hob is straightforward

by removing the control knobs, trivets, the burner caps and burner head assemblies and skirts. Using

a flat bladed screwdriver remove the five screws, one in each corner of the hotplates left and right spillage

bowls and one centrally located at the rear of the centre spillage bowl. Than lift the hob upwards.

Replacement is a reversal of the above procedure. Care must be taken to ensure that no damage occurs

to the spark ignition leads or the igniters. The electronic ignition pack is easily accessible for service or

replacement below the hob centrally at the ear.

ALWAYS ENSURE THAT THE POWER SUPPLY IS DISCONNECTED BEFORE SERVICING APPLIANCE

Gas Controls And Gas Manifold

Removal of the gas manifold is accomplished by removing the control knobs, the trivets, the

burner caps and burner head assemblies and skirts. Using a flat bladed screwdriver remove the five

screws, one in each corner of the hotplates left and right spillage bowls and one centrally located at the

rear of the centre spillage bowl. Care must be taken to ensure that no damage occurs to the spark ignition

leads, igniters or thermocouples (if fitted). Disconnect all ancillary gas piping. Remove the two securing

screws from the positioning brackets at the front and also the securing bracket near the gas inlet point to

the burner compartment. The gas manifold may than be extracted. Replacement is a reversal of the above

procedure.

ALWAYS ENSURE THAT THE GAS CONNECTION IS DISCONNECTED BEFORE SERVICING APPLIANCE

Conversion

If the appliance is to be used with another gas type, either ULPG Gas or Natural Gas, it must be converted

by an Authorised Person. Contact Eurolinx Pty Ltd or their unathorized agent for details. For Natural and

ULPG Gas Injector Sizes and Mj/H refer to tables on pages 39. The table above shows the

appropriate injector sizes for either ULPG Gas or Natural Gas.

NOTE

After conversion check the GAS PRESSURE and IGNITER OPERATION for the burners. If the hotplate

cooker cannot be adjusted to perform correctly, or if there is excessive flame discolouration, yellow tipping

or excessive noise contact ILVE or their authorised agent for advice. It is also recommended

that this appliance be serviced at 12 months minimum intervals or sooner as required. Please also ensure

that the duplicate data plate supplied be attached to the appliance or in an accessible place such as a

cupboard for future reference.

IMPORTANT:

Verify periodically the gas connection pipe and replace it as soon as any irregularity is present.

IMPORTANT:

Correct positioning of the brass flame distributor is very important. For this purpose, ensure that

the flame distributor tooth coincides with the notch on the aluminum base. To keep the flame

distributor covers new, you are advised to remove them before lighting the flame.