“S” SERIES - Installation and Connection

NOTE: PLUMBING AND ELECTRICAL CONNECTIONS SHALL BE MADE IN COMPLIANCE WITH APPLICABLE
LOCAL CONSTRUCTION CODES.

PLUMBING

Inlet: Cold water supply to disposer shall be

1

¼

2

" service line with a minimum of 20 lbs. flow pressure, piped as close

to disposer as possible. All disposer and control connections shall be

1

¼

2

" pipe size.

Sewer Outlet: 2" waste line should have trap with conveniently located clean out. Do not connect through a grease trap.
Avoid bends, elbows, tees, etc., to reduce the possibility of plumbing stoppage. A globe valve, used for metering flow,
must be installed between solenoid valve and cone or sink. Water swirl inlet valves should be located nearest operator.

See Typical Installation Diagram.

ELECTRICAL

Follow guidelines set forth by NEC standards. Disposer branch circuit shall be sized and fused (circuit breakers) as
required by motor. The disposer must be connected to a grounded, metal, permanent wiring system; or a disposer-
grounding conductor must be run with the circuit conductors and connected to the disposer-grounding terminal or lead
on disposer. All connections, junction boxes and conduits must be watertight (NEMA 4).

TESTING

See Start-up and Run Section.

THREE PHASE

208-230 Volts, 60 Hz

460 Volts, 60 Hz

190-220 Volts, 50 Hz

380 Volts, 50 Hz

Tied Together and Insulated

*

L1

L2

L3

1
7
2
8
3
9
4
5
6

4
7
1
5
8
2
6
9
3

L1

L2

L3

Table Cutout

13” for 12” cone
16” for 15” cone
19” for 18” cone

4 3/4” for 12” cone
5 1/2” for 15” cone
6 1/4” for 18” cone

Drain

13 1/2”

(14 1/2”)*

Drain

Disposer shown with regular drum

and sink mounting assembly

Disposer shown with offset drum

and cone mounting assembly

Adjustable 0” TO 2”

Adjustable 0” TO 2”

1” Min.

6” Max.

1” Min.

6” Max.

1” Min.

6” Max.

1”

7”

8”

8”

Cutout

Water

Inlet

7 3/8”

1”

7”

8” length of neoprene connector sleeve
furnished. May be cut to desired length.

NOTE: All dimensions shown at 0” foot height adjustment.

22 1/2”

(23 1/2”)*

11 1/2”

(12 1/2”)*

27”

(28)

*

Water

Inlet

9 5/8’

7 3/8”

9

5/8”

13 1/2”

(14 1/2”)*

11 1/2”

(12 1/2”)*

MOTOR WIRING DIAGRAM

VOLTAGE-AMPERAGE TABLE

INSTALLATION DIAGRAM

*Ratings are for 60 Hz operation.

HP

THREE PHASE

Volts

Amps*

3

208
230
460

4.9
4.4
2.2

5

208
230
460

6.9
6.2
3.1