Electrical connections – InSinkErator SS-50 User Manual

Page 9

Advertising
background image

9

ELECTRICAL SHOCK

• Turn off the electrical supply to the disposer before

servicing. Test the circuit with a voltmeter or circuit

tester to ensure the power is off.

• Installation must conform to all local

electrical codes.

• All control centers and disposers must

be grounded.

• A properly fused disposer control (with a marked

"off" position) that disconnects all ungrounded

supply conductors must be installed at the

electrical supply source.

PROPERTY DAMAGE

• Disposers shipped from the factory are not wired

for a specific voltage. Refer to the motor

connection wiring diagram in the terminal box for

voltage instructions.

• Ensure the disposer motor voltage and phase

match that of the electrical supply.

• The disposer motor wiring connection is shown in

the disposer terminal box.

Electrical Connections

ELECTRICAL CONNECTIONS

To connect the disposer to the electricity:
1. Remove the screw in the center of the disposer

terminal box.

2. Pull the terminal box out of the stainless steel

trim shell.

3. Connect an electrical conduit connector to the hole in

the bottom of the exposed wiring compartment.

4. Connect the ground wire to the ground screw.
5. Connect the incoming wires to the motor leads. Make

sure the wiring connections are the same as those on

the electrical connection diagrams (see page 8).

6. Reinstall the terminal box cover on the trim shell.
7. Test the disposer to ensure the cutting elements

revolve and the water flows automatically. Make sure

the disposer is securely mounted and does not leak

from any of the connections.

ELECTRICAL SHOCK

Be careful not to pinch or damage the electrical

wires when installing the terminal box.

PERSONAL INJURY/PROPERTY DAMAGE

If the electrical installer is not experienced in

electrical installation, we recommend seeking

competent professional assistance. Disposer or

accessory damage due to improper installation is

not covered under warranty. All installations must

comply with local electrical codes.

NOTES:

• Pressure switches may be connected across the

line at 5 horsepower or less. Large horsepower

motors require connection in the pilot circuit of a

magnetic starter.

• The magnetic and manual starters supplied by

InSinkErator do not require heaters to complete the

circuit. InSinkErator disposers are equipped with

overload protectors.

• A time delay may only be used with a water

solenoid valve.

Advertising