PROBLEM

POSSIBLE CAUSE

SOLUTION

Waste Xpress stops unexpectedly.

Discharge chute misaligned.

Fuse blown or circuit breaker
tripped at power source.

Stop button on control center
has been pushed.

Reinstall discharge chute to ensure
proper fi t.

Replace fuse or reset circuit breaker.

Push start button on control center.

Water exits Waste Xpress
at front of cabinet.

Drain line has clog.

High water level.

Clear drain.

Add second waste outlet drain connect from
Waste Xpress cabinet to sewer connection
(recommended for trough applications).

Waste Xpress does not run,
but disposer and water run.

Contactor defective.

Auger motor defective.

Call service.

Call service.

No water spraying onto
auger screen.

Solenoid valve clogged.

Water turned off.

Solenoid valve defective.

Spray nozzles clogged.

Timer defective.

Timer not set properly.

Solenoid valve installed incorrectly.

Remove clog.

Turn on water.

Call service.

Replace nozzles.

Call service.

Call service.

Reinstall solenoid valve so arrow is pointing
in correct direction.

Water fl ows continuously before
controls are turned on.

Solenoid valve installed incorrectly.

Timer is not set properly.

Solenoid valve is defective.

Reinstall the water solenoid valve with the
arrow on the valve pointing in the direction
of the water fl ow.

Call service.

Replace solenoid valve.

Overload protector trips frequently.

Disposer is overloaded with
food waste.

Do not overload disposer with excessive
amounts of food waste.

SYSTEM TROUBLESHOOTING