PERSONAL INJURY

• For safe operation, The minimum required distance
from the table top or trough to the mounting fl ange

is 6 inches for standard body disposers
(as specifi ed by UL). See Figure 5.

• Moving shredder parts may cause serious injury if

a hopper or cone is not properly installed.

DISPOSER MOUNTING

The disposer can be mounted to the sink or trough
using a standard InSinkErator mount or an
InSinkErator mounting adaptor.

NOTE: The InSinkErator #5 Sink Flange can not be
used with the Waste Xpress system.

NOTE: InSinkErator must approve attachment to a
non-InSinkErator sink.

PROPERTY DAMAGE

To avoid excess vibration, InSinkErator
recommends a minimum countertop thickness
of 16 gage stainless steel.

Figure 5.

CLEAN THE DRAIN LINE

With a drain line auger, clear away all hardened waste
material in the horizontal drainpipe running from the
drain trap to the main waste line.

Installing Disposer

6 inch min.