MAC/MAT-INSP-RSP-5

4 Feb 2014

SECTION 2

Scheduled Maintenance Inspections

2-4

STEP

M-4, M-4B WATER PUMP SYSTEM

150 HRS

(WEEKLY)

250 HRS

(BI‐WEEKLY)

500 HRS

(MONTHLY)

1,000 HRS

(QUARTERLY)

5,000 HRS

(ANNUALLY)

MANHOURS 

PER 

INSPECTION

TOTAL 

ANNUAL 

MANHOURS

1

Remove water pump from unit and check: 
water pump impeller retaining bolt/nut 
for security and for damage or contact to 
the impeller, impeller keyways for wear 
and security, shaft bearings for signs of 
heating and wear, drive end shaft keyways 
for signs of damage and heating and seals 
for security, damage and over or under 
lubrication. Check volute case for damage 
or contact. Check both of the impeller 
wear rings for damage and excessive wear 
(0.020” or 0.5 mm nominal tolerance) 
Check packing mount for security. 
(Disassembly of water pump is required to 
perform these maintenance operations). 
Repair as required.

X

5

5

2A

(This Step For M‐4 Pump Only) Check 
shaft seals for excessive lubricant leakage 
and water leakage. Lubricate water pump 
with a manual grease gun only. When 
lubricating the drive motor side shaft 
bearing and the impeller end bearing, 
apply 16 to 20 squirts (injections) of 
grease (2 fl. oz. or 60 cc) to each. Apply 4 
or 5 squirts (injections) of grease to 
lantern ring grease fitting. Adjust, repair 
or replace as required.

X

0.3

6

2B

(This Step For M‐4B Pump Only) Check 
shaft seals for excessive lubricant leakage 
and water leakage. When lubricating, 
apply 5.5 fl oz (150 cc) of grease to the 
drive end bearing and 2.5 fl oz (75 cc) of 
grease to the impeller end bearing. 
Adjust, repair or replace as required.

X

6

3

Check water pump and drive motor for 
leaks, excessive vibration/noise leaks and 
evidence of excessive heating. Repair as 
required.

X

0.3

6

4

Check rope seals for excessive water 
leakage, compression, wear and 
overheating. Adjust rope packing seal 
packing gland or replace rope packing 
seals as required.

X

0.3

6

5

Check water pump inlet and discharge 
piping for security, leakage and 
misalignment. Repair leaks as required.

X

0.2

2

25 Total