Operation of variable quantity slow co, Gas release system – Mega Catch MCU-800 Ultra User Manual

Page 14

Advertising
background image

12

4. Push one end of the gas line firmly into the orange collet fitting on the Gas Regulator

unit. Push the other end of the gas line firmly into the black collet fitting in the panel
on the rear of the Mega-Catch™ unit (see figure 3.2). Gradually turn on the CO

2

gas by

turning the wheel on the top of the Gas Cylinder in an anti-clockwise direction.

5. Check for gas leaks from the Gas Cylinder, the Regulator and the gas line using a small

quantity of liquid detergent/soap thoroughly stirred in some water (simply brush or pour

this over the items to be checked). A gas leak can be detected by the appearance of

bubbles. If a leak is detected then turn off the CO

2

gas by turning the wheel on the Gas

Cylinder clockwise. Then disconnect the Gas Regulator and check that the “O” ring seal

is in place and is undamaged and then repeat the process. If there is still a leak from

the Gas Cylinder or the Gas Regulator refer to your gas supplier (see page 13, CO

2

Gas

Supplier section.) or email us ([email protected]).

6. To remove the gas line simply use two fingers to push the sides of the plastic collet

fitting inwards then, using the other hand, firmly pull the gas line out of the collet

fitting. If the line is damaged replace it. If however the damage is restricted to the end

of the line simply cut out the damaged area. (Note: the collets are the orange fitting
at the Regulator connection and the black fitting at the Trap connection). See figure
3.2.

ATTENTION: BEFORE INSTALLING OR REMOVING THE GAS REGULATOR ALWAYS ENSURE

THE GAS IS TURNED OFF BY TURNING THE ON/OFF WHEEL ON THE GAS CYLINDER

CLOCKWISE.

Operation of Variable Quantity Slow CO

2

Gas Release System

You can adjust the quantity of CO

2

gas being released from the ULTRA Trap by a simple touch

of the GAS SELECT button on the Programmable Timer. When the power is first turned on the

Trap automatically selects setting # 1 which is the lowest gas usage quantity. The GAS SELECT

button should be touched once to move to the next setting (indicated by the red light glowing

on the setting chosen). Touch the GAS SELECT button for the number of times necessary to

move to the setting # you wish to select.
Remember to reset the setting # after each time the power is switched off.
On setting # 1, a 20lb (9kgs) CO

2

Gas Cylinder can be operated continuously (i.e. 24 hours per

day) for over 6 months. Continuous use of the Trap on higher settings can waste CO

2

gas. We

recommend that the Trap be operated for no more than 8 hours a day at times so as to coincide

with peak mosquito activity. This might be increased to 12 hours a day if you are experiencing

a particularly heavy infestation of mosquitoes.

Advertising
This manual is related to the following products: