Pass control, Ppoll, Ppoll config or ppc – Measurement Computing Personal488 rev.3.0 For DOS & Windows 3.Xi User Manual

Page 317

Advertising
background image

15A. Driver488/DRV Commands

III. COMMAND REFERENCES - 15. Command References

III-302

Personal488 User’s Manual, Rev. 3.0

PASS CONTROL

SYNTAX

PASS CONTROL addr

addr

is a device address (primary with optional secondary) or the external device

name of the device to which control is passed.

RESPONSE

None

MODE

CA

BUS STATES

ATN

UNL, MLA, TAG, UNL, TCT, *ATN

SEE ALSO

ABORT, RESET, SEND

EXAMPLE

100 PRINT#1, "PASS CONTROL 22"

Control is passed to device 22.

110 PRINT#1,"STATUS"

Use STATUS to check control.

120 INPUT#1,A$

Wait until we are controller again

130 IF LEFT$(A$,1)"C" THEN 110

The

PASS CONTROL

command allows Driver488 to give control to another controller on the bus. After

passing control, Driver488 enters the Peripheral mode. If Driver488 was the System Controller, then it
remains the System Controller, but it is no longer the Active Controller. The Controller now has
command of the bus until it passes control to another device or back to Driver488. The System
Controller can regain control of the bus at any time by issuing an

ABORT

command.

PPOLL

SYNTAX

PPOLL

RESPONSE

Number in the range 0 to 255.

MODE

CA

BUS STATES

ATN

EOI <parallel poll response>, *EOI

SEE ALSO

PPOLL CONFIG, PPOLL UNCONFIG, PPOLL DISABLE, SPOLL

EXAMPLE

PRINT#1,"PPOLL"

Conduct a Parallel Poll

INPUT#2,PPSTAT

Receive the PPOLL status

The

PPOLL

(Parallel Poll) command is used to request status information from many bus devices

simultaneously. If a device requires service, it responds to a Parallel Poll by asserting one of the eight
IEEE 488 bus data lines (

DIO1

through

DIO8

, with

DIO1

being the least significant). In this manner,

up to eight devices may simultaneously be polled by the controller. More than one device can share
any particular

DIO

line. In this case, it is necessary to perform further Serial Polling to determine

which device actually requires service.

Parallel Polling is often used upon detection of a Service Request (

SRQ

), though it may also be

performed periodically by the controller. In either case,

PPOLL

responds with a number from

0

to

255

corresponding to the eight binary

DIO

lines. Refer to the manufacturer’s documentation for each

device to determine whether or not Parallel Poll capabilities are supported.

PPOLL CONFIG or PPC

SYNTAX

PPOLL CONFIG addr;response

or

PPC addr;response

addr

is a device address (primary with optional secondary) or an external device

name.

response

is the decimal equivalent of the four binary bits

S

,

P2

,

P1

, and

P0

where

S

is then Sense bit, while

P2

,

P1

, and

P0

assign the

DIO

bus data line

used for the response.

RESPONSE

None

MODE

CA

BUS STATES

ATN

UNL, MTA, LAG, PPC

SEE ALSO

PPOLL, PPOLL UNCONFIG, PPOLL DISABLE

EXAMPLE

See next page.