Attach the scale to the linear stage. Reference the preferred datum on the

interface drawing for either end or center index orientation.
Attach the scale to the slide with adhesive. Refer to page 6 for details

about the different methods available.
Be sure the grating surface of the scale faces the sensor. There is to be no

contact between the CE300 and the grating or damage may result.

2

The ChipEncoder CE300 should be installed on a printed circuit board (PCB) to

the electrical and mechanical specifications outlined on the interface drawings.

See page 5 for instructions on downloading interface drawings; and pages

3, 4 and 5 for information about the CE300, and CE300 to PCB assembly

instructions.

3

Page 4

If you wish to verify the encoder outputs using a digital oscilloscope to view

the A, B, and Index Window signals, please refer to page 4 for output signal

descriptions. The CE300 should not require any additional alignment as long

as the PCB and mechanical components have been fabricated and assembled

according to the mechanical dimensions and tolerances specified in the CE300

interface drawings.

ChipEncoder™ CE300

Encoder Mounting with Linear Scale

PCB

ChipEncoder

Linear Scale

Linear Stage

Axis

Alignment Tolerances

x

direction of motion

y

± 0.008” [0.20mm]

z

± 0.010” [0.25mm]

θ

x

± 1.5°

θ

y

± 1.5°

θ

z

± 2.0°

1