Linear encoder installation-using sin/cos signals – MicroE 1500V Mercury User Manual

Page 8

Advertising
background image

Page 6

2

3

Be sure power is off before
connecting the sensor.

Connect the M1500V to your
interface electronics using
the wire color/signal
assigments described on the
interface drawing.

Tighten the connector screws.

Power up the system.

Install the sensor on your mounting surface
referencing the appropriate datum surface as
shown on the interface drawing. Use 2 washers
per mounting screw.

Benching pins may be used to locate the sensor
if the system mechanical tolerances are adequate.
See data sheet for alignment tolerances, or keep
mounting screws loose for sensor alignment if
benching pins are not used.

Installation Instructions

Linear Encoders - Using Sin/Cos Signals - Mounting

1

Attach the scale to the base slide. Reference the
preferred datum on the interface drawing for
either end or center index orientation.

Depending on the mounting method, attach the
scale to the slide with adhesive. Refer to
pg. 12 for details.

Be sure the grating surface of the scale faces the
sensor. Insure that there is no contact between
these surfaces or damage may result.

Advertising